Products: Marine Applications
SMART ODME
The Oil Discharge Monitoring Equipment (Smart ODME)has been designed to provide means of monitoring,recording and controlling the ballast discharge inaccordance with the requirements of MEPC 108(49). Discharge limits are set at 30 Litres per nautical mile and atotal discharge expressed as a proportion of the previouscargo for dirty ballast. The requirements of the MARPOL Convention are that all oiltankers with a gross tonnage of 150 GRT and above musthave an oil discharge monitoring and control system installed, incorporating an approved oil content meter, witha starting interlock and an automatic overboard valvecontrol system. The Smart ODME includes all componentsrequired to meet MEPC 108(49) and is designed for easeof installation and maintenance. The requirements in IMO Resolution MEPC 108(49) apply totankers with a date of keel laying or equivalent stage ofconstruction of 1st of January 2005 or later.
Smart ODME Computer Module
Smart ODME Pump - Measuring Cell
| Measurement | |
| Oil types: | As Per MEPC 108(49) Requirements |
| Clean water calibration: | Automatic |
| Oil measurement range: | 0 - 1000 ppm all types |
| Resolution: | 1 ppm |
| Accuracy oil + solids : | As Per MEPC 108(49) Requirements |
| User Interface | |
| Display: | 4 line x 20 alphanumeric back lit LCD display |
| Control + Setup: | 3 button keypad incorporating real time system display |
| Input / Output | |
| Output: | USB and RS232 |
| Log Input: | 200 Contact Closures per nautical mile |
| GPS: | NMEA 0183 |
| Data Storage and Retrieval | |
| Calibration data: | Stored onboard microcontroller |
| Storage data: | Stored onboard mounted memory media |
| Data retrieval: | via LCD display or download to PC with Hyperterminal |
| Environmental & Sample | |
| Ambient temperature: | -10 to +50oC |
| Sample / clean water flow rate: | 0.5 - 4.0 litres / min |
| Sample / Inlet pressure: | 1 bar |
| System and Supply | |
| Supply voltage: | |
| Zenner Barrier/Computer Module: | 115 / 230V ac, 50 - 60Hz (Switchable) |
| Motor: | 380-440V ac, 50-60Hz, 3 phase |
| Supply voltage Consumption: | < 50 VA including solenoid valve |
| Approvals: | IMO MEPC 108 (49) and GL + USCG |
| Mounting options: | 3U 19” Rack or Cabinet (Computer Module) |
download spec sheet